GEORGIA STANDARDS xxx GA. STD. 1001B - PIPE CULVERT CONCRETE HEADWALL (8-99) xxx GA. STD. 1004A - RUBBLE MASONRY HEADWALLS FOR PIPE CULVERTS (8-99) xxx GA. STD. 1010 - CATCH BASINS WITH CAST IRON GRATE INLETS (9-99) xxx GA. STD. 1011A - BRICK MANHOLES (10-81) xxx GA. STD. 1011A PRECAST - PRECAST REINFORCED CONCRETE MANHOLE (6-75) xxx GA. STD. 1013 - CATCH BASIN WITH CASTINGS REINFORCED CONCRETE BASIN WITH HOOD-TYPE A (8-99) xxx GA. STD. 1017 - PIPE ARCH CULVERTS 18" TO 72" SPAN CONCRETE ENDWALLS (8-99) xxx GA. STD. 1018B - SAND CEMENT BAG RIP RAP FOR ENDWALL AND APRON (5-76) xxx GA. STD. 1019A - DROP INLETS (8-99) xxx GA. STD. 1019A PRECAST - PRECAST DROP INLETS (8-99) xxx GA. STD. 1019B - DROP INLETS TYPES V-1 AND V-2 (8-99) xxx GA. STD. 1029A - RIP RAP FOR STRUCTURAL PLATE PIPE AND PIPE ARCH CULVERTS (2-66) xxx GA. STD. 1030D - CONCRETE AND METAL PIPE CULVERTS (SHEET 1 Of 3) (9-01) xxx CONCRETE AND METAL PIPE CULVERTS (SHEET 2 Of 3) (9-01) xxx CONCRETE AND METAL PIPE CULVERTS (SHEET 3 Of 3) (9-01) xxx GA. STD. 1030P - CORRUGATED SMOOTH LINED POLYETHYLENE PIPE(PE) AND POLYVINYL CHLORIDE PIPE(PVC) (1-07) xxx GA. STD. 1031 - SAND CEMENT BAG DITCH CHECKS STONE RIP RAP DITCH CHECKS (7-97) xxx GA. STD. 1033B - CATCH BASINS (MAX. PIPE CONN. - 18" MAY BE USED IN 4' MEDIAN) (2 SHEETS) (2-98) xxx GA. STD. 1033D - CATCH BASINS (FOR USE WITH 6" OR 8" HT. CURB AND GUTTER) (8-82) xxx GA. STD. 1033D PRECAST - PRECAST CATCH BASINS (FOR USE WITH 6" OR 8" HT. CURB AND GUTTER) (9-82) xxx GA. STD. 1033E - CATCH BASINS (FOR USE WITH 4" HT. CURB AND GUTTER) (8-82) xxx GA. STD. 1033E PRECAST - PRECAST CATCH BASINS (FOR USE WITH 4" HT. CURB AND GUTTER) (9-82) xxx GA. STD. 1033F - CATCH BASINS (FOR USE WITH HEADER OR INTERGRAL CURBS, 4", 6", 8", OR 10" HT.) (8-82) xxx GA. STD. 1033F PRECAST - PRECAST CATCH BASINS (FOR USE WITH HEADER OR INTERGRAL CURBS, 4", 6", 8", OR 10" HT.) (9-82) xxx GA. STD. 1033G - CATCH BASINS (FOR USE WITH 6" MOUNTABLE CURB AND GUTTER) (12-85) xxx GA. STD. 1033G PRECAST - PRECAST CATCH BASINS (FOR USE WITH 6" MOUNTABLE CURB AND GUTTER) (12-85) xxx GA. STD. 1034D - CATCH BASINS (FOR USE WITH 6" OR 8" CURB AND GUTTER IN SAGS OR LOW POINTS) (8-82) xxx GA. STD. 1034D PRECAST - PRECAST CATCH BASINS (FOR USE WITH 6" OR 8" CURB AND GUTTER IN SAGS OR LOW POINTS) (9-82) xxx GA. STD. 1034E - CATCH BASINS (FOR USE WITH 4" HT. CURB AND GUTTER IN SAGS OR LOW POINTS) (8-82) xxx GA. STD. 1034E PRECAST - PRECAST CATCH BASINS (FOR USE WITH 4" HT. CURB AND GUTTER IN SAGS OR LOW POINTS) (9-82) xxx GA. STD. 1034F - CATCH BASINS (FOR USE WITH 4", 6", 8" OR 10" HT. HEADER OR INTEGRAL CURBS-IN SAGS OR LOW POINTS) (8-82) xxx GA. STD. 1034F PRECAST - PRECAST CATCH BASINS (FOR USE WITH 4", 6", 8" OR 10" HT. HEADER OR INTEGRAL CURBS-IN SAGS OR LOW POINTS) (9-82) xxx GA. STD. 1034G - CATCH BASINS (FOR USE WITH 6" MOUNTABLE CURB AND GUTTER IN SAGS OR LOW POINTS) (12-85) xxx GA. STD. 1034G PRECAST - PRECAST CATCH BASINS (FOR USE WITH 6" MOUNTABLE CURB AND GUTTER IN SAGS OR LOW POINTS) (12-85) xxx GA. STD. 1035 - DRAIN INLET (ELBOW TYPE AND ALTERNATE)FOR YARD DRAINS (11-99) xxx GA. STD. 1040 - CIRCULAR BASE UNITS AND RISERS FOR CATCH BASINS AND DROP INLETS (11-99) xxx GA. STD. 1120 - FLARED END SECTIONS FOR PIPES (6-06) xxx GA. STD. 1122 - SAFETY END SECTION (METAL) ((SHEET 1 OF 3) (1-05) SAFETY END SECTION (METAL) (SHEET 2 OF 3) (1-05) SAFETY END SECTION (CONCRETE) (SHEET 3 OF 3) (1-05) xxx GA. STD. 1125 - TAPERED INLET HEADWALL - OUTLET HEADWALL (10-99) xxx GA. STD. 1401 - PAVEMENT PATCHING DETAILS (STORM DRAIN OR UTILITY INSTALLATIONS BY OPEN CUT ACROSS EXISTING PAVEMENT) (8-99) xxx GA. STD. 2010 - CORRUGATED METAL PIPE ARCH CULVERTS SPANS 6 FT. 0 IN. TO 20 FT. 0 IN. INCLUSIVE (2 SHEETS) (6-98) xxx GA. STD. 2011B - STRUCTURAL PLATE PIPE AND PIPE ARCH CULVERTS (10-99) xxx GA. STD. 2312 - DETAILS FOR EXTENDING CULVERTS (RAISING PARAPETS OR LENGTHENING CULVERTS 2' OR LESS) (7-58) xxx GA. STD. 2317 - DETAILS FOR EXTENDING CONCRETE BOX CULVERTS (1-66) xxx GA. STD. 2318 - DETAILS FOR EXTENDING CONCRETE BOX CULVERTS WITH SKEWS BELOW 75^ (7-78) xxx GA. STD. 2319A - REINFORCED CONCRETE BOX CULVERTS QUADRUPLE 10' X 10' FOR DEPTHS OF FILL UP TO 50 FEET (11-01) xxx GA. STD. 2319B - (11-01) xxx GA. STD. 2320A - REINFORCED CONCRETE BOX CULVERTS DOUBLE 10' X 8', 10' X 9', AND 10' X 10' FOR DEPTHS OF FILL UP TO 50 FEET. (11-01) xxx GA. STD. 2320B - (11-01) xxx GA. STD. 2320C - REINFORCED CONCRETE BOX CULVERTS DOUBLE 10' X 8', 10' X 9', 10' X 10' FOR 45^, 60^ AND 75^ SKEWS (11-01) xxx GA. STD. 2320D - (7-81) xxx GA. STD. 2321 - REINFORCED CONCRETE BOX CULVERTS SINGLE 3' X 2' TO SINGLE 6' X 6' FOR DEPTHS OF FILL UP TO 20 FEET. (2 SHEETS) (11-01) xxx GA. STD. 2322 - REINFORCED CONCRETE BOX CULVERTS SINGLE 4' X 6', SINGLE 5' X 6' FOR DEPTHS OF FILL UP TO 20 FEET. ( 11-01) xxx GA. STD. 2323 - REINFORCED CONCRETE BOX CULVERTS SINGLE 7' X 4' TO SINGLE 9' X 10' FOR DEPTHS OF FILL UP TO 20 FEET. (2 SHEETS) (11-01) xxx GA. STD. 2324 - REINFORCED CONCRETE BOX CULVERTS SINGLE 10' X 4' THRU SINGLE 10' X 12' FOR DEPTHS OF FILL UP TO 20 FEET. (2 SHEETS) (11-01) xxx GA. STD. 2325 - REINFORCED CONCRETE BOX CULVERTS DOUBLE 3' X 2'6" TO TRIPLE 6' X 6' FOR DEPTHS OF FILL UP TO 20 FEET. (2 SHEETS) (11-01) xxx GA. STD. 2326 - REINFORCED CONCRETE BOX CULVERTS DOUBLE 7' X 4' TO TRIPLE 9' X 10' FOR DEPTHS OF FILL UP TO 20 FEET. (2 SHEETS) (11-01) xxx GA. STD. 2327 - REINFORCED CONCRETE BOX CULVERTS DOUBLE 10' X 4' TO TRIPLE 10' X 12' FOR DEPTHS OF FILL UP TO 20 FEET. (2 SHEETS) (11-01) xxx GA. STD. 2328 - REINFORCED CONCRETE BOX CULVERTS SINGLE 3' X 2' TO TRIPLE 6' X 6' FOR 75^, 60^ AND 45^ SKEWS (3 SHEETS) (11-01) xxx GA. STD. 2329 - REINFORCED CONCRETE BOX CULVERTS SINGLE 7' X 4' TO TRIPLE 9' X 10' FOR 75^, 60^ AND 45^ SKEWS (4 SHEETS) (11-01) xxx GA. STD. 2330 - REINFORCED CONCRETE BOX CULVERTS SINGLE 10' X 4' TO TRIPLE 10' X 12' FOR 75^, 60^ AND 45^ SKEWS (4 SHEETS) (11-01) xxx GA. STD. 2331 - REINFORCED CONCRETE BOX CULVERT WINGWALLS AND PARAPETS QUANTITIES SINGLE 3' X 2' TO TRIPLE 10' X 12' FOR 75^, 60^, AND 45^ SKEW (11-01) xxx GA. STD. 2332 - CONCRETE BOX CULVERT APRONS, BAFFLES AND INLET BEVELING DETAIL AND ADJACENT BOX CULVERT JOINT DETAIL (2 SHEETS) (6-98) xxx GA. STD. 2530P - PRECAST BOX CULVERT BARRELS 4'X 3' THRU 10' X 10' SINGLE AND MULTIPLE LINES (6-85) xxx GA. STD. 2535P - PRECAST BOX CULVERT ENDS - WINGWALLS, PARAPETS TOEWALLS AND APRONS (3-85) xxx GA. STD. 3054 - END POST AND END POST GUARDRAIL ATTACHMENT DETAIL (9-02) xxx GA. STD. 3215 - SQUARE PRESTRESSED CONCRETE PILES (2-84) xxx GA. STD. 3626 - ONE PIPE ALUMINUM HANDRAILING FOR BRIDGES (10-85) xxx GA. STD. 3632 - TWO PIPE ALUMINUM HANDRAILING FOR MOUNTING ON BRIDGE PARAPETS (10-85) xxx GA. STD. 3901 - BAR BENDING DETAILS (8-69) xxx GA. STD. 4000W - GUARDRAIL WARRANT GUIDES (9-07) xxx GA. STD. 4010 - "W" BEAM GUARDRAIL (5-99) xxx GA. STD. 4011A - POST AND OFFSET BLOCKS FOR "W" AND "T" BEAM (12-01) xxx GA. STD. 4012C - GUARDRAIL CONNECTION AT BRIDGE END OR AT CONCRETE BARRIER END (3-05) xxx GA. STD. 4012D - GUARDRAIL ANCHORAGE TYPE 1 (7-02) xxx GA. STD. 4013 - GUARDRAIL ANCHORAGE TYPE 5 AND 6 AND GUARDRAIL ATTACHMENT TO COLUMNS, PIERS WALLS (6-98) xxx GA. STD. 4022A - LOCATION OF GUARDRAIL IN MEDIANS LOCATION OF GUARDRAIL AT TURNOUTS (3-03) xxx GA. STD. 4030 - DETAILS OF GALVANIZED METAL CIRCULAR GUARDRAIL FOR PROTECTION OF R.R.SIGNALS (6-98) xxx GA. STD. 4040 - GUARDRAIL ANCHORAGE TYPE 12 (4-06) xxx GA. STD. 4051 - GUARDRAIL LOCATION DETAILS FOR MULTI-LANE DIVIDED HIGHWAYS (10-97) xxx GA. STD. 4052 - GUARDRAIL LOCATION DETAILS FOR UNDIVIDED HIGHWAYS AND ROADS (10-97) xxx GA. STD. 4055 - GUARDRAIL LOCATION AT FIXED OBJECTS IN MEDIAN (7-98) xxx GA. STD. 4057 - LOCATION OF CONTINUOUS DOUBLE FACED GUARDRAIL IN MEDIAN (REPLACES CONSTRUCTION DETAIL G-9) (8-99) xxx GA. STD. 4058 - EMERGENCY VEHICLE OPENINGS FOR CONTINUOUS DOUBLE FACED GUARDRAIL IN MEDIAN (REPLACES CONST. DETAIL) (8-99) xxx GA. STD. 4270 - "T" BEAM GUARDRAIL. (11-99) xxx GA. STD. 4280 - GUARDRAIL LOCATION (ON ROADS WITH CURB AND GUTTER, HEADER CURB OR INTEGRAL CURB) (10-99) xxx GA. STD. 4360 - REFLECTORIZED GUARDRAIL WASHERS AND ANCHORAGE NOSE STRIPING (4-06) xxx GA. STD. 4940 - CONCRETE MEDIAN BARRIER - PERMANENT (TYPES 20, 21, 22 AND 7-M AND CONC. GLARE SCREEN) (12-88) xxx GA. STD. 4948A - CONCRETE SIDE BARRIER TYPES 7-C, 7-R, 7-T AND 7-W (12-99) xxx GA. STD. 4948B - CONCRETE SIDE BARRIER TYPES 2, 2-A, 2-B AND 2-C (1-07) xxx GA. STD. 4948C - CONCRETE SIDE BARRIER TYPES 6, 6-A, 6-B AND 6-C (1-00) xxx GA. STD. 4960 - CONCRETE BARRIER - TEMPORARY (END TREATMENT OPTIONS) (5-07) xxx GA. STD. 4961 - DETAILS OF PRECAST TEMPORARY BARRIERS (9-06) xxx GA. STD. 4962 - TEMPORARY TRAFFIC IMPACT ATTENUATOR - SAND LOADED MODULES (5-99) xxx GA. STD. 5001M - DROP INLET TYPES M-1 AND M-2 ADJACENT TO CONCRETE BARRIER (2 SHEETS) (6-98) xxx GA. STD. 5046H - JOINT DETAILS FOR PLAIN PORTLAND CEMENT CONCRETE PAVING (1-07) xxx GA. STD. 9003 - DETAILS OF MARKERS FEDERAL AID AND STATE PROJECT MARKERS; RIGHT OF WAY MARKERS; COUNTY LINE MARKERS (4-06) xxx GA. STD. 9013 - CONCRETE SPILLWAYS (TYPICAL USE: ALONG ROADWAY AT END OF CURB) (2-81) xxx GA. STD. 9017C - CATCH BASIN (PRECAST OR BUILT-IN-PLACE ADJACENT TO APPROACH SLAB) (6-85) xxx GA. STD. 9017J - CONCRETE SPILLWAYS (ADJACENT TO APPROACH SLABS) (2-95) xxx GA. STD. 9017K - REINFORCED CONCRETE APPROACH SLAB - 30 FT. LENGTH(TYPICAL USE: CURB OR CURB AND GUTTER ADJACENT TO ROADWAY AND/OR SIDEWALK ACROSS BRIDGE) (6-85) xxx GA. STD. 9017L - REINFORCED CONCRETE APPROACH Slab 20 FT. (TYPICAL USE: CURB AND GUTTER ADJACENT TO ROADWAY AND/OR SIDEWALK ACROSS BRIDGE) (6-85) xxx GA. STD. 9017M - REINFORCED CONCRETE APPROACH SLAB 30 FT. LENGTH (WITH CONCRETE BARRIER) (6-93) xxx GA. STD. 9017N - REINFORCED CONCRETE APPROACH SLAB 20 FT. LENGTH (WITH CONCRETE BARRIER) (6-93) xxx GA. STD. 9017P - REINFORCED CONCRETE APPROACH SLAB 30 FT. LENGTH ( TYPICAL USE: WHERE SHOULDER IS ADJACENT TO ROADWAY AND/OR BRIDGE) (9-02) xxx GA. STD. 9017Q - REINFORCED CONCRETE APPROACH SLAB 20 FT. LENGTH (TYPICAL USE: WHERE SHOULDER IS ADJACENT TO ROADWAY AND/OR ACROSS BRIDGE (2-90) xxx GA. STD. 9017R - REINFORCED CONCRETE APPROACH SLAB W/ASPHALT INLAY 30 FT. LENGTH (TYPICAL USE: WHERE SHOULDER IS ADJACENT TO ROADWAY AND/OR BRIDGE) (9-02) xxx GA. STD. 9021A - RAILROAD GRADE CROSSING PAVING (AND SIGNAL CONDUIT LOCATIONS) (9-82) xxx GA. STD. 9022A - RAILROAD GRADE CROSSING GATES AND CANTILEVERS (11-94) xxx GA. STD. 9023A - RAILROAD GRADE CROSSING SIGNS AND MARKINGS (4-06) xxx GA. STD. 9024A - RAILROAD GRADE CROSSING - RAILROAD SIGNING AND MARKINGS AT CROSSING WITH RR SIGNALS AND/OR GATES (10-96) xxx GA. STD. 9025A - RAILROAD CROSSING AT HIGHWAY WITH A 14 FT. CENTER LANE (2-08) xxx GA. STD. 9029B - PERFORATED UNDERDRAIN (8-83) xxx GA. STD. 9030C - DELINEATORS AND OBJECT MARKERS AND ALTERNATE (4-06) xxx GA. STD. 9031G - GROUTED RUBBLE SPILLWAYS (OR APRONS) (2-66) xxx GA. STD. 9031H - DETAIL FOR PLUGGING DRILLED WELL, STATIONING OF CONCRETE PAVEMENT, CONCRETE SLAB WELL COVER, DETAIL OF TURNOUTS - RURAL (10-87) xxx GA. STD. 9031L - RETAINING WALL TYPICAL SECTIONS, RAISING HEADWALL AND TYPICAL PIPE PLUG (SHEET 1 OF 2) (6-98) DETAILS OF: CATCH BASINS MODIFIED FOR DOUBLE GRATE, DROP INLET MODIFIED FOR DOUBLE GRATE, CONCRETE SPRING BOX, CONCRETE STEPS, CATCH BASINS OR DROP INLET CONNECTION TO CONCRETE BOX CULVERT, CAPPING EXISTING DROP INLET (SHEET 2 OF 2) (6-98) xxx GA. STD. 9031N - CHAIN-LINK WIRE FENCE (8-85) xxx GA. STD. 9031R - PLACING ROOF DRAIN PIPE UNDER SIDEWALK- RAMP TYPE BARRICADE- PIPE HANDRAIL FOR RETAINING WALL- PIPE HANDRAIL FOR CONCRETE STEPS (10-88) xxx GA. STD. 9031S - MEDIAN DROP INLET (PRECAST OR BUILT-IN-PLACE) AND CONCRETE APRON. (4-96) xxx GA. STD. 9031T - ISOMETRIC VIEWS OF SIDE ROAD OR DRIVEN FLARE DETAIL AT BRIDGE ENDS (8-95) xxx GA. STD. 9031U - JUNCTION BOXES (PRECAST OR BUILT-IN-PLACE) PIPE COLLARS, PIPE ELBOW AND PIPE CURVED ALIGNMENT (7-85) xxx GA. STD. 9032B - CONCRETE CURB AND GUTTER, CONCRETE CURBS, CONCRETE MEDIANS (3-03) xxx GA. STD. 9033 - MILEPOSTS (3-06) xxx GA. STD. 9037 - TYPICAL FILL DETAIL AT END OF BRIDGE (99-99) xxx GA. STD. 9039 - PERMANENT TIMBER TYPE BARRICADE (3-06) xxx GA. STD. 9041 - ASSEMBLY DETAILS ON ALUMINUM BOLTED EXTRUDED PANELS (FOR SPECIAL ROADSIDE SIGNS) (8-93) xxx GA. STD. 9042 - ALUMINUM BOLTED EXTRUDED PANELS ASSEMBLY COMPONENTS DETAILS (FOR SPECIAL ROADSIDE SIGNS) (9-66) xxx GA. STD. 9046A - EARTH SPUR DIKE (9-99) xxx GA. STD. 9054A - ERECTION AND FOUNDATION DETAILS FOR SPECIAL ROADSIDE SIGNS - BREAKAWAY POST (10-81) xxx GA. STD. 9054B - ERECTION AND FOUNDATION DETAILS FOR SPECIAL ROADSIDE SIGNS - BREAKAWAY TYPE POST (3-87) xxx GA. STD. 9054C - ERECTION AND FOUNDATION DETAILS FOR SPECIAL ROADSIDE SIGNS - BREAKAWAY TYPE POST (10-81) xxx GA. STD. 9055 - ERECTION AND FOUNDATION DETAILS FOR SPECIAL ROADSIDE SIGNS - BREAKAWAY TYPE POST (WOOD) (TO BE USED ONLY WHERE SPECIFIED) (6-83) xxx GA. STD. 9100 - TRAFFIC CONTROL GENERAL NOTES, STANDARD LEGEND, AND MISCELLANEOUS DETAILS (REPLACES CONST. DETAIL T-9) (3-06) xxx GA. STD. 9102 - TRAFFIC CONTROL DETAIL FOR LANE CLOSURE ON TWO-LANE HIGHWAY (3-06) xxx GA. STD. 9106 - TRAFFIC CONTROL DETAIL FOR LANE CLOSURE ON MULTI-LANE DIVIDED HIGHWAY (3-06) xxx GA. STD. 9107 - TRAFFIC CONTROL DETAIL FOR LANE CLOSURE ON MULTI-LANE DIVIDED HIGHWAY (3-06) xxx GA. STD. 9108 - TRAFFIC CONTROL DETAIL - TYPICAL BY-PASS DETOUR FOR 2-LANE HIGHWAY (3-06) xxx GA. STD. 9109 - TRAFFIC CONTROL DETAIL - TYPICAL DETOUR ACROSS MEDIAN (3-06) xxx GA. STD. 9110 - DETAIL FOR OVERSIZE TRUCK DETOUR IN CONSTRUCTION AREAS (11-99) xxx GA. STD. 9121 - TAPERS, SIGNS, AND MARKINGS FOR PASSING LANES (3-06) CURRENT AS OF July 16, 2008